When troubleshooting a 100 GbE SR4 (MPO‑type B) link on a robotic controller chassis, a common source of intermittent loss is a mismatch between the native 100 GbE configuration and a 4 × 25 GbE breakout that the host or switch may be attempting to negotiate. The first step is to confirm the physical topology: SR4 modules are native 100 GbE, while a breakout requires a compatible QSFP‑28 to 4×SFP‑28 or MPO‑to‑LC fan‑out cable that is explicitly rated for 25 GbE per lane. If a plain MPO‑to‑MPO cable is used without a breakout adapter, the host may still see four logical lanes but the transceiver firmware will report a “DOM Mode” identifier of 0x03 (native 100 GbE) rather than 0x04 (25 GbE breakout). Check the DOM Rx power per lane; native 100 GbE typically shows ‑4 dBm ± 2 dB, whereas 25 GbE lanes appear around ‑8 dBm ± 2 dB. A quick CLI query (e.g., show interface eth0 dom) can reveal the mode and per‑lane power. If the values are mixed—some lanes at ‑4 dBm and others at ‑8 dBm—it often indicates a partially seated MPO connector or a hybrid cable that is not fully compatible. Verify the host’s port configuration (speed‑auto vs forced 100 GbE) and ensure the switch side is set to the same mode. A practical checklist: 1) Identify the transceiver part numbers on both ends; 2) Confirm cable type matches the intended mode; 3) Query DOM mode and Rx power; 4) Reseat MPO connectors and re‑test; 5) If still failing, replace with a known‑good breakout assembly.
What diagnostic command or tool do you find most reliable for distinguishing native 100 GbE from a 4 × 25 GbE breakout on a mixed‑vendor chassis?