When a robot arm uses an eye‑in‑hand camera, systematic drift can appear after a thermal cycle or a tool change. A practical diagnostic flow starts with confirming that the camera module is still mechanically bonded: verify the mounting torque against the vendor spec (typically 0.8‑1.2 Nm for M3 screws) and inspect for any visible gap or twist in the mount. Next, capture a fresh set of calibration images on a high‑contrast checkerboard placed at multiple depths (e.g., 200 mm, 400 mm, 600 mm) covering the full field of view. Use the same image resolution and exposure settings as in production; typical exposure for indoor lighting is 10‑20 ms, but confirm that the histogram does not saturate. Run the intrinsic calibration and compare the reprojection error to the last known good baseline (often <0.25 px RMS). If the error exceeds that threshold, re‑run the calibration with additional poses.
Assuming intrinsics are stable, verify extrinsics by moving the arm to at least five predefined poses used in the original hand‑eye calibration. Record the pose matrices and compute the average transformation error; a common acceptable range is <1 mm translation and <0.5° rotation. If errors are larger, check for any recent tool‑holder replacement: the tool’s tip offset must be updated in the robot’s kinematic model.
Finally, log the temperature of the camera and the arm joint at the time of calibration; a temperature rise of more than 5 °C from the baseline can explain a shift in focal length or lens distortion parameters. Adjust the temperature compensation table if the vendor provides one.
What is the most reliable method you have found to detect a subtle shift in the camera‑to‑tool transform without re‑running a full hand‑eye calibration?
Assuming intrinsics are stable, verify extrinsics by moving the arm to at least five predefined poses used in the original hand‑eye calibration. Record the pose matrices and compute the average transformation error; a common acceptable range is <1 mm translation and <0.5° rotation. If errors are larger, check for any recent tool‑holder replacement: the tool’s tip offset must be updated in the robot’s kinematic model.
Finally, log the temperature of the camera and the arm joint at the time of calibration; a temperature rise of more than 5 °C from the baseline can explain a shift in focal length or lens distortion parameters. Adjust the temperature compensation table if the vendor provides one.
What is the most reliable method you have found to detect a subtle shift in the camera‑to‑tool transform without re‑running a full hand‑eye calibration?