When a 100 GbE SR4 transceiver is installed, the first diagnostic step is to confirm whether the module is operating in native 100 GbE mode or as a 4 × 25 GbE breakout. The transceiver’s EEPROM (SFF‑8472) contains a “Connector Type” field that distinguishes SR4 (LC duplex) from QSFP‑28 breakout (MPO‑14 with 4×LC). A second check is the DOM (Digital Optical Monitoring) mode identifier: native SR4 reports a single aggregate Rx power value, whereas a breakout reports four per‑lane Rx power entries. Verify the host NIC’s lane mapping via the NIC’s management interface (e.g., ethtool –S or vendor‑specific CLI) – the lane bitmap should show either four lanes combined (100 GbE) or four independent lanes (25 GbE). If the host reports four separate lanes, ensure the MPO‑type matches the module (Type A vs Type B polarity). Next, compare the measured per‑lane Rx power against the module’s specification; typical SR4 Rx power is –8 dBm to –2 dBm per lane, while 25 GbE breakout lanes are –10 dBm to –4 dBm. Any deviation beyond the specified range may indicate a fiber fault or mis‑polarity. Finally, confirm that the host’s SerDes equalization settings are set for the appropriate data rate (100 GbE vs 25 GbE) to avoid eye‑diagram degradation.